ENERGY USE ATLAS / SECURITY ENERGY TOOLS
Security Camera
Electricity Cost Calculator
Find out how much electricity your security cameras and CCTV system use, and what they cost to run.
- Single cameras and complete CCTV systems
- NVR, DVR and PoE support
- Day and night power usage
- Instant cost calculations
Estimated monthly electricity cost
—Average calendar month
How to Use the Security Camera Electricity Cost Calculator
Start with Quick estimate if your cameras are alike. Choose a type, enter how many cameras you have, and adjust the suggested watts and operating schedule. Replace the example electricity price with the energy rate from your bill. Use your local currency and enter what you pay for one kilowatt-hour.
Use Advanced system to split cameras by model or schedule. You can enter separate day and night wattages, add recorders and networking equipment, and estimate losses from power delivery. Choose Measured usage if you have a kWh reading for the entire system. The reading covers every device included in that measurement.
How Much Electricity Does a Security Camera Use?
Two cameras of the same type can draw different amounts of power. Indoor WiFi cameras may have fixed lenses and small infrared emitters. Outdoor models may add powerful LEDs or heaters. A fixed PoE camera gets data and power over Ethernet. Pan-tilt-zoom (PTZ) cameras can draw more power while their motors move. Analog CCTV systems can include separately powered cameras and a DVR.
Check the camera’s actual operating draw and features before relying on a preset. A camera can keep its sensor, processor and network connection active while motion-triggered recording is idle. For battery or solar cameras, estimate only the electricity you actually buy, such as energy drawn by a mains charger during a representative period.
How to Calculate CCTV Electricity Cost
Energy (kWh) = watts × operating hours ÷ 1,000
Electricity cost = energy (kWh) × price per kWh
For each group, multiply day and night watts by the hours spent in those states, add the two values, then multiply by the number of cameras. Add any separately entered light usage. For camera-side PoE power, divide the result by the estimated delivery efficiency as a decimal. Add independently scheduled recorder, drive and accessory energy once each.
The calculator multiplies energy per active day by operating days per week. A 365-day year uses 365 ÷ 7 weeks, and the average calendar month uses one-twelfth of that annual total. The separate 30-day estimate equals 30 average days. Continuous-equivalent power spreads annual usage over all 8,760 hours.
Worked example · Four PoE cameras
Four cameras running at 6 W for 12 hours and 9 W for 12 hours each use 0.720 kWh per day together. At 90% delivery efficiency, the cameras draw 0.800 kWh at the supply. A 12 W NVR and one 5 W drive, both running 24/7, add 0.408 kWh.
1.208 kWh/day · 440.92 kWh/year · $79.37/year · $6.61 per average month at an illustrative USD $0.18/kWh.
Does Night Vision Increase Security Camera Electricity Usage?
Infrared LEDs and white spotlights draw energy when active. Use a nighttime wattage that reflects the camera’s actual operating state. If that figure includes its infrared LEDs, it already accounts for their load. For a separately estimated spotlight, use its additional watts and actual hours lit per day. A light triggered for six minutes per hour over a ten-hour night would run for one hour total.
How Much Electricity Does an NVR or DVR Use?
The recorder electronics and installed drives can draw power as long as the unit is on. If your measurement covers both, choose the option for recorder wattage that includes drives. Enter a PoE recorder or switch’s own draw separately from camera output. If you measured a recorder and its connected cameras together at the wall, use Measured usage for that combined reading. A power brick’s capacity is a maximum supply rating.
How to Measure Your Security Camera’s Actual Electricity Consumption
A suitable plug-in meter can measure energy at an AC outlet. Record elapsed hours and kWh over a representative 24-hour period or longer, covering night vision, normal recording and other regular activity. Keep the projection schedule consistent with the power states included in the observation. For camera-side measurement, use equipment specified for the PoE standard in use. Camera-side readings can exclude switch overhead and delivery losses.
What the estimate covers. This is the energy portion of the electricity bill. Purchase, installation, repair, internet and cloud subscriptions, fixed charges, demand charges, complex tiers and taxes outside the entered rate are excluded. Shared equipment such as a household router contributes only if you choose to include its draw.
Frequently Asked Questions
How much electricity does a security camera use per day?
A camera averaging 5 W and running all day uses 0.12 kWh per day. Use your own average watts and hours for a model-specific estimate.
How much does it cost to run one camera 24/7?
At 5 W and $0.18/kWh, one camera uses 43.8 kWh and costs $7.88 over a 365-day year.
How much electricity do four CCTV cameras use?
Four cameras averaging 5 W each use 0.48 kWh per day when running continuously. Include any recorder, network equipment and delivery losses separately.
How much does an eight-camera CCTV system cost to run?
Eight cameras averaging 5 W each use 350.4 kWh a year when running continuously, or $63.07 at $0.18/kWh. A complete estimate also includes any recorder, accessories and delivery losses.
Does night vision increase electricity consumption?
Active infrared LEDs or spotlights can add to draw. Enter observed night watts, or add extra spotlight watts only when the camera power figure excludes that light.
Does PoE use more electricity than WiFi?
It depends on the cameras, their settings and the power source. Compare similar wall-side measurements or model the delivery losses and dedicated accessories for both setups.
Does an NVR use electricity when cameras are not recording?
Usually. An on recorder may keep its processor, network connection and drives active between recordings. Measure an average across normal operation.
Can I calculate costs for multiple cameras?
Yes. Use one quantity for identical cameras, or use up to 20 independently scheduled groups in Advanced system.
Is the Security Camera Electricity Cost Calculator free?
Yes. The calculator runs in your browser without an account.
Can I calculate CCTV electricity costs in Indian rupees?
Yes. Select INR and enter your local electricity price in rupees per kWh. Changing currency clears the previous rate.
How Much Electricity Does a Security Camera Use?
Security cameras consume electricity whenever they are operating, whether they are monitoring your front door, recording activity around a business, or providing continuous surveillance through a CCTV system.
A basic indoor WiFi camera may use only a few watts, while outdoor cameras with infrared night vision, motorized movement, or integrated floodlights can require considerably more power. Complete surveillance systems also consume electricity through network video recorders (NVRs), digital video recorders (DVRs), hard drives, and networking equipment.
The Security Camera Electricity Cost Calculator above helps estimate the daily, monthly, and annual electricity consumption of individual cameras and complete CCTV installations.
You can enter camera wattage, quantity, operating hours, electricity rates, and additional equipment to calculate your estimated running costs. The calculator also supports different daytime and nighttime consumption values, making it useful for cameras with infrared illumination and other power-intensive features.
Security Camera Electricity Consumption by Type
Different security cameras have different power requirements. Their consumption depends on hardware specifications, recording functions, lighting features, and operating conditions.
The following table provides illustrative wattage values for understanding how various camera configurations affect electricity consumption.
| Security Camera Type | Example Operating Power |
|---|---|
| Indoor WiFi camera | 4–5 W |
| Outdoor WiFi camera | 6–9 W |
| PoE bullet camera | 5–9 W |
| PoE dome camera | 5–9 W |
| Analog CCTV camera | 4–6 W |
| PTZ security camera | 11–18 W |
| Floodlight security camera | Varies significantly with lighting |
These are illustrative calculation ranges, not verified averages for all cameras in each category. Actual power consumption may fall outside these values.
Manufacturer specifications demonstrate this variation. For example, Reolink lists full-load consumption below 5 W for certain indoor WiFi camera models, while some of its PoE floodlight cameras have maximum power ratings of 28 W.
A camera’s maximum rated power should not automatically be treated as its continuous consumption. Many cameras use less electricity during ordinary operation than their maximum rating suggests.
Does Night Vision Increase Electricity Consumption?
Yes, infrared night vision can increase a security camera’s power consumption.
Many security cameras use infrared LEDs to illuminate their surroundings in low-light conditions. Activating these LEDs requires additional electricity, although the increase depends on the camera’s design.
Other features that can affect electricity consumption include:
- Integrated LED spotlights and floodlights.
- Motorized pan, tilt, and zoom functions.
- Built-in heaters and cooling fans.
- Video processing and advanced analytics.
- Active tracking and multiple video streams.
For a more accurate estimate, enter separate daytime and nighttime wattages in the calculator.
If the nighttime wattage already includes infrared illumination, do not add the infrared power again.
How Much Does It Cost to Run a Security Camera 24/7?
Most continuously powered security cameras are designed to remain operational throughout the day and night.
Even relatively low electricity consumption adds up over months of uninterrupted operation.
Consider three hypothetical security cameras operating continuously at an illustrative electricity rate of $0.18 per kWh.
| Average Power | Daily Electricity | Annual Electricity | Annual Cost |
|---|---|---|---|
| 5 W | 0.12 kWh | 43.8 kWh | $7.88 |
| 10 W | 0.24 kWh | 87.6 kWh | $15.77 |
| 15 W | 0.36 kWh | 131.4 kWh | $23.65 |
Assumptions: Constant average power, 24-hour daily operation, 365 days annually, and $0.18/kWh. These are hypothetical calculation examples, not guaranteed costs or a current national electricity rate.
A camera averaging 10 W would therefore cost approximately $15.77 annually under these assumptions, excluding additional recording and networking equipment.
Your actual electricity cost will depend on the camera’s average power consumption and your local electricity tariff.
How to Calculate CCTV Electricity Cost
The basic electricity calculation uses three variables: power consumption, operating time, and electricity price.
Electricity consumption (kWh) = Power (W) × Operating Hours ÷ 1,000
Electricity cost = Consumption (kWh) × Electricity Rate ($/kWh)
For example, a 10 W security camera operating for 24 hours consumes:
10 × 24 ÷ 1,000 = 0.24 kWh per day
Over 365 days:
0.24 × 365 = 87.6 kWh per year
At $0.18/kWh:
87.6 × $0.18 = $15.77 per year
For an entire CCTV system, calculate the electricity used by each camera and include any separately powered recorders, hard drives, PoE equipment, or dedicated accessories.
Example: Electricity Cost of a Four-Camera CCTV System
Consider an illustrative home surveillance setup consisting of four PoE cameras, one NVR, and one hard drive.
Assume:
- Four cameras consuming 6 W during the day and 9 W at night.
- 12 daytime hours and 12 nighttime hours.
- A PoE power-delivery efficiency of 90%.
- An NVR consuming 12 W, excluding cameras and hard drives.
- One hard drive consuming 5 W.
- Continuous operation throughout the year.
- An electricity rate of $0.18/kWh.
The cameras consume 0.72 kWh daily before accounting for PoE losses.
At the assumed 90% power-delivery efficiency, camera supply consumption increases to 0.80 kWh daily.
The NVR and hard drive consume an additional 0.408 kWh per day.
Estimated total system consumption:
| Measurement | Result |
|---|---|
| Daily electricity usage | 1.208 kWh |
| Annual electricity usage | 440.92 kWh |
| Average monthly electricity cost | $6.61 |
| Annual electricity cost | $79.37 |
This example demonstrates why a complete CCTV power consumption calculator is more useful than estimating camera wattage alone.
Actual results vary with equipment specifications, operating conditions, and power-delivery efficiency.
How Much Electricity Does an NVR or DVR Use?
A network video recorder or digital video recorder can contribute substantially to a surveillance system’s total electricity consumption.
An NVR generally manages video streams from connected IP cameras and may provide PoE power to those cameras. A DVR commonly records footage from analog CCTV cameras.
Electricity consumption can include the recorder’s internal electronics, installed hard drives, cooling components, and connected equipment.
For example, a recorder consuming 12 W and a hard drive consuming 5 W would together use 17 W.
If operated continuously, this equals:
17 × 24 × 365 ÷ 1,000 = 148.92 kWh annually
At $0.18/kWh, the estimated annual electricity cost would be approximately $26.81, excluding cameras and other devices.
When calculating electricity usage, avoid counting camera power twice. If a measured NVR power figure already includes the electricity supplied to connected PoE cameras, those cameras should not be added again.
Do PoE Cameras Use More Electricity Than WiFi Cameras?
Not necessarily.
Power over Ethernet (PoE) cameras receive electrical power and network connectivity through an Ethernet cable. WiFi cameras generally communicate wirelessly but still require power from an adapter, battery, or another source.
The camera’s hardware and features determine much of its electricity consumption, not simply whether it uses PoE or WiFi.
However, PoE installations can introduce additional power losses through cables and power-delivery equipment.
The calculator allows applicable power-delivery efficiency to be included when estimating complete system consumption.
A measured electricity figure taken at the AC wall outlet generally already includes the relevant upstream power losses, so those losses should not be added again.
How to Measure Security Camera Electricity Consumption
Manufacturer specifications provide a useful starting point, but measuring actual electricity consumption can produce a more representative estimate.
For an adapter-powered WiFi camera, a compatible plug-in electricity meter can measure consumption at the wall outlet.
For PoE cameras, compatible PoE monitoring equipment or network switches with power-monitoring functionality may provide camera-side power readings.
For complete systems, measuring the electricity consumed by the recorder and its connected equipment can help establish total running costs.
For reliable estimates:
- Measure consumption across typical operating conditions.
- Include both daytime and nighttime operation.
- Account for active infrared lighting and spotlights.
- Distinguish actual measurements from maximum rated wattage.
- Avoid adding components already included in a whole-system measurement.
Measurements covering a representative day or longer may provide a better estimate than short readings taken during a single operating state.
Frequently Asked Questions
How much electricity does a security camera use per day?
It depends on wattage and operating hours. A security camera averaging 5 W and operating continuously consumes approximately 0.12 kWh per day. A 10 W camera consumes 0.24 kWh daily under the same conditions.
How much does it cost to run a security camera 24/7?
A camera averaging 10 W uses 87.6 kWh annually when operated continuously. At an illustrative rate of $0.18/kWh, the annual electricity cost is approximately $15.77, excluding additional surveillance equipment.
How much electricity do four CCTV cameras use?
Four cameras averaging 8 W each consume a combined 32 W. Running continuously, they use approximately 0.768 kWh daily or 280.32 kWh annually, before adding recorders and power-delivery losses.
How much does an eight-camera CCTV system cost to run?
Eight cameras averaging 8 W each consume 560.64 kWh annually when operating continuously. At $0.18/kWh, their combined camera-only electricity cost is approximately $100.92 annually. NVRs, hard drives, and power losses increase the total system cost.
Does night vision increase security camera electricity usage?
It can. Infrared LEDs and integrated spotlights require electricity when activated. The additional power depends on the camera model and lighting features.
Does a security camera use electricity when it is not recording?
Generally, yes. A powered security camera may continue monitoring, processing video, maintaining network connectivity, or detecting motion even when it is not actively saving recordings.
Does an NVR consume electricity all the time?
An NVR consumes electricity while powered on. Its actual consumption depends on its hardware, recording activity, installed hard drives, and whether it supplies electricity to connected PoE cameras.
Can I calculate electricity costs for multiple security cameras?
Yes. The Security Camera Electricity Cost Calculator supports multiple camera configurations, allowing you to estimate combined electricity consumption and operating costs based on quantity, wattage, schedules, and supporting equipment.
Is the Security Camera Electricity Cost Calculator free?
Yes. Energy Use Atlas provides this calculator as a free online tool for estimating security camera and CCTV electricity consumption. No account is required to perform calculations.
Can I calculate CCTV electricity costs in Indian rupees?
Yes. Select INR (₹) and enter the applicable electricity rate in rupees per kWh. The calculator can estimate running costs using your chosen currency and tariff. It does not automatically determine your local electricity rate.
Calculate Your Security Camera Electricity Cost
A security camera’s running cost depends on more than its advertised wattage. Camera quantity, operating hours, infrared night vision, recording hardware, and power-delivery efficiency can all influence total electricity consumption.
For the most useful estimate, enter your actual camera specifications, include supporting equipment where appropriate, and use the variable electricity rate from your utility bill.
The Security Camera Electricity Cost Calculator above helps you understand daily, monthly, and annual power consumption, estimate electricity expenses, and compare surveillance configurations using transparent calculations.
Results are estimates based on the information provided. Actual electricity bills may include fixed charges, taxes, and other fees beyond the calculated energy cost.